Jumat, 22 November 2019
Kamis, 21 November 2019
Gudang Pendingin Second Garansi 2 Tahun 081936999998
Kami Menjual Split Cold Room / Ruangan Pendingin atau Pembeku Mesin di Luar. Tersedia 3 macam ukuran standard Cold Room , pemasangan sangat mudah dan hemat biaya pemasangan Mesin (Condensing Unit) biasanya diletakan di luar ruangan supaya ruangan tidak terlalu panas. Aplikasi : Mini Market, Toko daging, Toko buah, Hotel, Restaurant, Laboratorium, Rumah sakit.
Fitur :
- Ketebalan panel Polyurethane 10 cm
- Density 40 - 42 kg/m3
- Bahan luar / dalam : Hot dipped galvanis colorbond
- Camlock
- Pintu dilengkapi kunc i + safety handle
- System Knock-Down
- Strip curtain
- Mesin Split (Evaporator , Condenser + Compressor terpisah)
- Kompressor L'Unite (Tecumseh)
1 SPESIFIKASI SPLIT COLD ROOM TYPE GAC-75S :
* Dimensi Unit : 200 x 200 x 250 cm
* Accesories : 1 set strip curtain, 1 set lampu TL 36W
1A. SPLIT COLD ROOM TYPE GAC-75S SUHU +2 ~ +4 'C (CHILLER / UNTUK PRODUK SUDAH DINGIN) :
* Volume : 7,5 M3
* Kaps. Penyimpanan : 1500 Kg
* Condensing Unit : CAJ-9510T
* Power : 1229 watt / 220V
* Refrigerant : R22
* Evaporator : DD1.4/311B
* Harga : Rp. 75.000.000
1B. SPLIT COLD ROOM TYPE GAC-75S SUHU -20'C (FREEZER / UNTUK PRODUK SUDAH BEKU) :
* Volume : 7,5 M3
* Kaps. Penyimpanan : 2600 Kg
* Condensing Unit : CAJ-2464Z
* Power : 1118 watt / 220V
* Refrigerant : R404
* Evaporator : DD1.4/311B
* Harga : Rp. 75.000.000
1C. SPLIT COLD ROOM TYPE GAC-75S SUHU -20'C (FREEZER / UNTUK PRODUK SUDAH BEKU) :
* Volume : 7,5 M3
* Kaps. Penyimpanan : 1500 Kg
* Condensing Unit : TFH-2480Z
* Power : 1628 watt / 220V
* Refrigerant : R404
* Evaporator : DD2.3/311B
* Harga : Rp. 85.000.000
2. SPESIFIKASI SPLIT COLD ROOM TYPE GAC-116S :
* Dimensi Unit : 300 x 200 x 250 cm
* Accesories : 1 set strip curtain, 1 set lampu TL 36W
2A. SPLIT COLD ROOM GAC-116S SUHU +2 ~ +4 'C (CHILLER / UNTUK PRODUK SUDAH DINGIN) :
* Volume : 11,6 M3
* Kaps. Penyimpanan : 2.600 Kg
* Condensing Unit : CAJ-4519T
* Power : 2304 watt / 220V
* Refrigerant : R22
* Evaporator : DD2.3/311B
* Harga : Rp 89.000.000
2B. SPLIT COLD ROOM GAC-116S SUHU -20'C (FREEZER / UNTUK PRODUK SUDAH BEKU) :
* Volume : 11,6 M3
* Kaps. Penyimpanan : 4.500 Kg
* Condensing Unit : TFH-2480Z
* Power : 1628 watt / 380V
* Refrigerant : R404
* Evaporator : DD2.3/311B
* Harga : Rp. 99.000.000
2C. SPLIT COLD ROOM GAC-116S SUHU -20'C (FREEZER / UNTUK PRODUK SETENGAH BEKU) :
* Volume : 11,6 M3
* Kaps. Penyimpanan : 2.600 Kg
* Condensing Unit : TFH-2511Z
* Power : 2105 watt / 380V
* Refrigerant : R404
* Evaporator : DD2.3/311B
* Harga : Rp. 99.000.000
3. SPESIFIKASI PLUG IN COLD ROOM TYPE GAC-245S :
* Dimensi Unit : 400 x 300 x 250 cm
* Dimensi Lubang Panel Atap : 115 x 46 cm
* Accesories : 1 set strip curtain, 1 set lampu TL 36W
3A. SPLIT COLD ROOM GAC-245S SUHU +2 ~ +4 'C (CHILLER / UNTUK PRODUK SUDAH DINGIN) :
* Volume : 24,5 M3
* Kaps. Penyimpanan : 5.600 Kg
* Condensing Unit : FH-4524F
* Power : 2456 watt / 220V
* Refrigerant : R22
* Evaporator : DD2.3/311B
* Harga : Rp. 110.000.000
3B. SPLIT COLD ROOM GAC-245S SUHU -20'C (FREEZER / UNTUK PRODUK SUDAH BEKU) :
* Volume : 24,5 M3
* Kaps. Penyimpanan : 6.400 Kg
* Condensing Unit : TFH-2511Z
* Power : 2456 watt / 380V
* Refrigerant : R404
* Evaporator : DD2.3/311B
* Harga : Rp. 120.000.000
3C. SPLIT COLD ROOM GAC-245S SUHU -20'C (FREEZER / UNTUK PRODUK SETENGAH BEKU) :
* Volume : 24,5 M3
* Kaps. Penyimpanan : 5.600 Kg
* Condensing Unit : TAG-2516Z
* Power : 3146 watt / 380V
* Refrigerant : R404
* Evaporator : DD3.0/312B
* Harga : Rp. 125.000.000
** BIAYA PEMASANGAN CHILLER 17,5% DAN FREEZER 20%
Air Blast Freezer Second Garansi 081936999998
Oil Pressure Control (OPC)
Oil Pressure Differential
Berfungsi untuk memproteksi kompresor / mematikan kompresor apabila tekanan pompa oli dibawah differential yg telah ditentukan.
Prinsip Kerja:
Ketika Kompresor mulai bekerja, Pompa mechanical pelumas yg digerakkan oleh poros engkol (crankshaft) juga mulai memompa pelumas. Pasa saat awal mulai bekerja tekanan pompa pelumas belum stabil. Diperlukan waktu dibawah 120 detik (tergantung aplikasi, ada yg menggunakan time delay 45, 60, 90, dan 120 detik) agar tekanan pompa pelumas menjadi stabil (tekanan keluaran pompa naik lebih dari 9 psi dari tekanan hisapnya).
Jika dalam waktu yg telah ditentukan tekanan keluaran pompa dan tekanan hisapnya masih dibawah 9 psi maka rangkaian timer pada Oil Pressure Differential ini akan memutus rangkaian listrik untuk mematikan Kompresor.
Penyebab turunnya tekanan pelumas:
1. Kerusakan pada bagian mekanik dari pompa pelumas.
2. Kurangnya pelumas di bagian crankcase kompresor
3. Tersumbatnya aliran pelumas di bagian hisap pompa atau jika sistem menggunakan Oil Separator biasanya terjadi penyumbatan pada jarum pengontrol aliran pelumas di Oil Separator.
Langkah Perbaikan:
1. Kerusakan mekanis bisa dilakukan perbaikan dgn cara overhaul bagian pompa pelumas dan mengganti spare part yg rusak.
2. Jika pelumas kurang (bisa dilihat di oil level indicator) maka kita tinggal tambahkan saja agar pelumas mencapai level sesuai dgn ketentuan manufacture-nya).
3. Tersumbatnya saluran suction pompa pelumas biasanya terjadi pada saringan di bagian crankcase kompresor (bersihkan saringan dan ganti pelumas dgn yg baru). Kalau terjadi penyumbatan di Oil Separator , bersihkan Oil Separator tsb, jika O/S model hermetic lebih baik ganti dgn yg baru.